over operating free-air temperature range (unless otherwise noted)(1) | MIN | MAX | UNIT |
---|
VCC | Supply voltage(2) | | 36 | V |
VID | Differential input voltage(3) | | ±36 | V |
VI | Input voltage range (either input) | –0.3 | 36 | V |
IK | Input current(5) | | –50 | mA |
VO | Output voltage | | 36 | V |
IO | Output current | | 20 | mA |
| Duration of output short circuit to ground(4) | Unlimited | |
TJ | Operating virtual-junction temperature | | 150 | °C |
| Case temperature for
60s | FK package | | 260 | °C |
| Lead temperature 1.6mm
(1/16in) from case for 60s | J package | | 300 | °C |
Tstg | Storage temperature | –65 | 150 | °C |
(1) Stresses beyond those listed under Absolute Maximum Ratings
can cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those
indicated under Recommended Operating Conditions is not implied. Exposure
to absolute-maximum-rated conditions for extended periods can affect device
reliability.
(2) All voltage values, except differential voltages, are with respect to network ground.
(3) Differential voltages are at xIN+ with respect to xIN–.
(4) Short circuits from outputs to VCC can cause excessive heating and eventual destruction.
(5) Input current flows through parasitic diode to ground and can turn on parasitic
transistors that can increase ICC and
can cause output to be incorrect. Normal operation
resumes when the input is removed.