SLVS503F November 2003 – February 2020 TPS2490 , TPS2491
PRODUCTION DATA.
請參考 PDF 數(shù)據(jù)表獲取器件具體的封裝圖。
The GATE driver is enabled if the positive threshold is exceeded and the internal POR and UVLO thresholds have been satisfied. EN can be used as a logic control input, an analog input voltage monitor as illustrated by R1/R2 in the Figure 18 circuit, or it can be tied to VCC to always enable the TPS249x. The hysteresis associated with the internal comparator makes this a stable method of detecting a low input condition and shutting the downstream circuits off. A TPS2490 that has latched off can be reset by cycling EN below its negative threshold and back high.