ZHCAAE5B November 2019 – January 2024 LM4040-N , LM4050-N , LM4120 , LM4128 , LM4128-Q1 , LM4132 , LM4132-Q1 , REF102 , REF1925 , REF1930 , REF1933 , REF1941 , REF20-Q1 , REF200 , REF2025 , REF2030 , REF2033 , REF2041 , REF2125 , REF2912 , REF2920 , REF2925 , REF2930 , REF2933 , REF2940 , REF30 , REF3033-Q1 , REF31-Q1 , REF3112 , REF3120 , REF3125 , REF3130 , REF3133 , REF3140 , REF3212 , REF3212-EP , REF3220 , REF3220-EP , REF3225 , REF3225-EP , REF3230 , REF3230-EP , REF3233 , REF3240 , REF3312 , REF3318 , REF3320 , REF3325 , REF3330 , REF3333 , REF34-Q1 , REF3425 , REF3425-EP , REF3430 , REF3430-EP , REF3433 , REF3433-EP , REF3440 , REF3440-EP , REF3450 , REF35 , REF4132 , REF4132-Q1 , REF50 , REF5020-EP , REF5020A-Q1 , REF5025-EP , REF5025-HT , REF5025A-Q1 , REF5030A-Q1 , REF5040-EP , REF5040A-Q1 , REF5045A-Q1 , REF5050-EP , REF5050A-Q1 , REF50E , REF54 , REF6125 , REF6133 , REF6141 , REF6145 , REF6150 , REF6225 , REF6230 , REF6233 , REF6241 , REF6245 , REF6250 , REF70 , TL431LI , TL432LI , TLV431
溫漂體現(xiàn)的是基準(zhǔn)電壓隨溫度的變化。此規(guī)范通常由箱形法定義。有關(guān)箱形法計(jì)算過(guò)程的更多詳細(xì)信息,請(qǐng)參閱 TI 的《基準(zhǔn)電壓選擇基礎(chǔ)知識(shí)》 白皮書(shū)。由于非線性特性,在選擇正確的溫漂時(shí)有幾個(gè)考慮因素。其中一個(gè)考慮因素是,溫漂通常被定義為一個(gè)平均值,在特定地區(qū)可以大于或小于平均值。溫漂曲線的形狀會(huì)根據(jù)參考架構(gòu)和使用的曲率校正方法以線性或非線性方式變化。一個(gè)常見(jiàn)的誤解是,電壓基準(zhǔn)源、埋入式齊納或帶隙會(huì)決定器件的最終溫漂曲率。事實(shí)并非如此,因?yàn)榇蠖鄶?shù)電壓基準(zhǔn)源都有用于修整和調(diào)整溫度曲率的外圍電路,這會(huì)調(diào)整基準(zhǔn)源的溫度形狀。表 3-2 所示為溫漂和誤差百分比之間的關(guān)系,以演示如何將溫漂與精度進(jìn)行比較。
溫度系數(shù) (ppm/°C) | 從 0°C 到 70°C 的誤差 (%) | 從 -40°C 到 85°C 的誤差 (%) | 從 -40°C 到 125°C 的誤差 (%) |
---|---|---|---|
1 | 0.0070 | 0.0125 | 0.0165 |
5 | 0.0350 | 0.0625 | 0.0825 |
10 | 0.0700 | 0.1250 | 0.1650 |
50 | 0.3500 | 0.6250 | 0.8250 |
100 | 0.7000 | 1.2500 | 1.6500 |